Symptom |
Fault |
Action |
Carbonation |
Flat Drinks |
CO2 Cylinder Valve Closed |
Open The CO2 Cylinder Valve |
CO2 Cylinder Empty |
Change The CO2 Cylinder, Pull Off 4 Pints Of Soda Water |
CO2 Pressure Low |
Change The CO2 Cylinder |
Drink Too Warm |
Clean Or Clear The Refrigeration Grills/Switch The Unit On |
Excessive Foaming |
Dirty Nozzle/Diffuser |
Clean The Dispenser Nozzle/Diffuser |
Drink Too Warm |
Clean Or Clear The Refrigeration Grills/Switch The Unit On |
Large CO2 Consumption |
Empty Bag In Box |
Replace The Empty Bag-In-Box With A Fresh Bag-In-Box Of The Same Flavour. If No Change Of Box Is Available Then Submerge Bag-In-Box Connector Into Water |
Sealing Washer Link |
Check The Sealing Washer Is In Place |
Taste |
Too Weak/Strong |
CO2 Pressure Low |
Change The CO2 Cylinder |
Dispensed Valve Out Of Adjustment |
Call Us On: 01455 233228 |
Off Taste |
Dirty Nozzle |
Clean The Dispenser Nozzle/Diffuser |
Wrong Flavour Connected |
Connect Syrup Line To Correct Flavour & Open Valve Until Rectified |
Dirty Product Line |
Call Us On: 01455 233228 |
Flavour Strength |
No Syrup |
Empty Bag In Box |
Replace Empty Bag In Box With A Fresh Bag-In-Box Of The Same Flavour |
Line Obstruction |
Free Lines Of Any Restrictions |
Faulty Change-Over (Where Fitted) |
Manually Switch Change-Over Valve To Full Bag In Box |
CO2 Cylinder Valve Closed |
Open The CO2 Cylinder Valve |
CO2 Cylinder Empty |
Change The CO2 Cylinder |
Faulty Syrup Pump |
Call Us On: 01455 233228 |
No Carbonated Water |
Water Off |
Open Mains Water Stop Cock |
CO2 Cylinder Valve Closed |
Open The CO2 Cylinder Valve |
Reset Button Trapped |
Press Reset Button Or Unplug At Socket For 3 Seconds |
Temperature |
Drink Too Warm |
Refrigeration Unit Not Working |
Check Main Power Supply, Switch On Power For Refrigeration Unit |
Insufficient Airflow Through Condenser (Dirty Grill) |
Clean Cooler/Condenser Grill |
Grill Obstruction |
Remove Any Objects Blocking Air Into Or Out Of The Refrigeration Unit |