| Symptom | Fault | Action |
|---|---|---|
| Carbonation | ||
| Flat Drinks | CO2 Cylinder Valve Closed | Open The CO2 Cylinder Valve |
| CO2 Cylinder Empty | Change The CO2 Cylinder, Pull Off 4 Pints Of Soda Water | |
| CO2 Pressure Low | Change The CO2 Cylinder | |
| Drink Too Warm | Clean Or Clear The Refrigeration Grills/Switch The Unit On | |
| Excessive Foaming | Dirty Nozzle/Diffuser | Clean The Dispenser Nozzle/Diffuser |
| Drink Too Warm | Clean Or Clear The Refrigeration Grills/Switch The Unit On | |
| Large CO2 Consumption | Empty Bag In Box | Replace The Empty Bag-In-Box With A Fresh Bag-In-Box Of The Same Flavour. If No Change Of Box Is Available Then Submerge Bag-In-Box Connector Into Water |
| Sealing Washer Link | Check The Sealing Washer Is In Place | |
| Taste | ||
| Too Weak/Strong | CO2 Pressure Low | Change The CO2 Cylinder |
| Dispensed Valve Out Of Adjustment | Call Us On: 01455 233228 | |
| Off Taste | Dirty Nozzle | Clean The Dispenser Nozzle/Diffuser |
| Wrong Flavour Connected | Connect Syrup Line To Correct Flavour & Open Valve Until Rectified | |
| Dirty Product Line | Call Us On: 01455 233228 | |
| Flavour Strength | ||
| No Syrup | Empty Bag In Box | Replace Empty Bag In Box With A Fresh Bag-In-Box Of The Same Flavour |
| Line Obstruction | Free Lines Of Any Restrictions | |
| Faulty Change-Over (Where Fitted) | Manually Switch Change-Over Valve To Full Bag In Box | |
| CO2 Cylinder Valve Closed | Open The CO2 Cylinder Valve | |
| CO2 Cylinder Empty | Change The CO2 Cylinder | |
| Faulty Syrup Pump | Call Us On: 01455 233228 | |
| No Carbonated Water | Water Off | Open Mains Water Stop Cock |
| CO2 Cylinder Valve Closed | Open The CO2 Cylinder Valve | |
| Reset Button Trapped | Press Reset Button Or Unplug At Socket For 3 Seconds | |
| Temperature | ||
| Drink Too Warm | Refrigeration Unit Not Working | Check Main Power Supply, Switch On Power For Refrigeration Unit |
| Insufficient Airflow Through Condenser (Dirty Grill) | Clean Cooler/Condenser Grill | |
| Grill Obstruction | Remove Any Objects Blocking Air Into Or Out Of The Refrigeration Unit | |