SymptomFaultAction
Carbonation
Flat DrinksCO2 Cylinder Valve ClosedOpen The CO2 Cylinder Valve
CO2 Cylinder EmptyChange The CO2 Cylinder, Pull Off 4 Pints Of Soda Water
CO2 Pressure LowChange The CO2 Cylinder
Drink Too WarmClean Or Clear The Refrigeration Grills/Switch The Unit On
Excessive FoamingDirty Nozzle/DiffuserClean The Dispenser Nozzle/Diffuser
Drink Too WarmClean Or Clear The Refrigeration Grills/Switch The Unit On
Large CO2 ConsumptionEmpty Bag In BoxReplace The Empty Bag-In-Box With A Fresh Bag-In-Box Of The Same Flavour. If No Change Of Box Is Available Then Submerge Bag-In-Box Connector Into Water
Sealing Washer LinkCheck The Sealing Washer Is In Place
Taste
Too Weak/StrongCO2 Pressure LowChange The CO2 Cylinder
Dispensed Valve Out Of AdjustmentCall Us On: 01455 233228
Off TasteDirty NozzleClean The Dispenser Nozzle/Diffuser
Wrong Flavour ConnectedConnect Syrup Line To Correct Flavour & Open Valve Until Rectified
Dirty Product LineCall Us On: 01455 233228
Flavour Strength
No SyrupEmpty Bag In BoxReplace Empty Bag In Box With A Fresh Bag-In-Box Of The Same Flavour
Line ObstructionFree Lines Of Any Restrictions
Faulty Change-Over (Where Fitted)Manually Switch Change-Over Valve To Full Bag In Box
CO2 Cylinder Valve ClosedOpen The CO2 Cylinder Valve
CO2 Cylinder EmptyChange The CO2 Cylinder
Faulty Syrup PumpCall Us On: 01455 233228
No Carbonated WaterWater OffOpen Mains Water Stop Cock
CO2 Cylinder Valve ClosedOpen The CO2 Cylinder Valve
Reset Button TrappedPress Reset Button Or Unplug At Socket For 3 Seconds
Temperature
Drink Too WarmRefrigeration Unit Not WorkingCheck Main Power Supply, Switch On Power For Refrigeration Unit
Insufficient Airflow Through Condenser (Dirty Grill)Clean Cooler/Condenser Grill
Grill ObstructionRemove Any Objects Blocking Air Into Or Out Of The Refrigeration Unit